Find A Listing

Need to find a listings? It’s as easy as 1… 2… 3…!

  1. Select the Building Type under the classification you require.
  2. Use the Easy-to-Use chart to find the right listing.
  3. Click on the listing number … the listing PDF will pop up!
If you require additional help, you can always give us a call on our technical support line… 1-800-853-3984.
  • UL Architectural Chart
    RATING (HR) JOINT TYPE JOINT WIDTH UL SYSTEM NO. PRODUCT
    2 Curtain Wall to Concrete Floor 8 in. max CW-D-2034 and CW-D-2035 SL-100 / MW-300
    1 and 2 Head of G.W.B. to Metal Deck  (Optional Structural Steel Support) 1 in. nominal HW-D-0382 GG-200 / MW-300
    2 Head of Masonry Wall to Metal Deck (Optional Structural Steel Support) 1 in. max HW-S-0021 and HW-D-0459 GG-200 / MW-300
    1 and 2 Head of G.W.B. to Concrete Floor 1 in. max HW-S-0060 GG-200
    2 Concrete Floor Joint Incorporating Membrane Air Barrier 4 in. max FF-S-1031 SL-100 / MW-300
    2 Concrete Floor to Wall Joint Incorporating Membrane Air Barrier 4 in. max FW-S-1016 SL-100 / MW-300
    3 Horizontal Concrete Expansion Joint 4 in. nominal FF-D-1036 SL-100 / MW-300
    3 Vertical Concrete Expansion Joint 4 in. nominal WW-D-1036 GG-200 / MW-300
    2 Head of Masonry Wall to Concrete Floor 1 in. max HW-S-0079 GG-266
    3 Head of Masonry Wall to Concrete Floor 4 in. nominal HW-D-1032 GG-200 / MW-300
    3 Concrete Floor to Masonry Wall 4 in. nominal FW-D-1033 SL-100 / MW-300
    2 Stair Assembly 4 in. nominal FW-D-1045 GG-200 / MW-300
    1 and 2 Head of G.W.B. to Steel Deck/Concrete Floor 2 in. nominal HW-D-0661 GG-200 / MW-300
    2 Head of Masonry Wall to Steel Deck/Concrete Floor 2 in. nominal HW-D-0662 GG-200 / MW-300
    2 Head of Masonry Wall to Concrete Floor 4 in. nominal HW-D-1097 GG-200 / MW-300
  • UL Mechanical Charts
    RATING (HR) PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCTS
    CONCRETE – METALLIC PIPE and DUCTWORK
    3 Blank Opening No Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-0048  SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    3 3″ Copper / 4″ Steel / 4” Cast Iron (Shielded Coupling) No Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-1227 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 and 3 4” Copper / 8” Steel No Concrete Slab / Block Wall Steel 10-1/2 in. diam C-AJ-1369 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” Copper / 8” Steel No 2-1/2” Concrete Slab No 10-1/2 in. diam C-AJ-1452 SL-100, GG-200 or GG-266 / MW-300
    2 (T Rating) 4” Copper / 10” Steel 2” or 3” Mineral Fiber Concrete Slab / Block Wall No 12 in. diam C-AJ-1554 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 (T Rating) 4” Cast Iron (Optional Shielded Coupling) 1” Mineral Fiber Concrete Slab / Block Wall No 6 in. diam C-BJ-1061 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” Copper / 8” Steel No Concrete Slab No 10-1/2 in. diam F-A-1021 GG-200 / MW-300 (Underside Floor Application)
    2 4” Copper / 8” Steel No Concrete Slab No 8-5/8 to 9-1/8 in. Cone Shape F-A-1055 SL-100, GG-200 or GG-266 / MW-300 (Floors only)
    2 3” Copper / 3” Steel 1” Glass Fiber Concrete Slab / Block Wall Steel 6 in. diam C-AJ-5163 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    3 3″ Copper / 4″ Steel 1” Mineral Fiber Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-5092 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 16” Steel 1” or 1-1/2” Mineral Fiber Concrete Slab / Block Wall No 576 sq. in. C-AJ-5093 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 and 3 3” Copper / 8” Steel 1”, 1-1/2” or 2” Glass Fiber Concrete Slab / Block Wall No 14 in. diam C-AJ-5204 & C-AJ-5307 GG-266 / MW-300
    2 6” Copper / 16” Steel 1-1/2”, 2”, 2-1/2” or 3” Cellular Glass Insulation Concrete Slab / Block Wall Steel 24 in. diam C-AJ-5228 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 (T Rating) 4” Copper / 8” Steel with Optional Pipe Fittings 2” or 3” Mineral Fiber Concrete Slab / Block Wall No 10 in. diam C-AJ-5229 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 (T Rating) 4” Copper, Steel, Cast Iron 3/4” AB / PVC   Flexible Foam Concrete Slab / Block Wall No 8 in. diam C-AJ-5293 GG-266 / MW-300 (Walls and Floors)
    1 and 2 3″ Copper / 4″ Steel No Concrete Slab / Hollow-Core Floor / Block Wal No 6 in. diam C-AJ-1201 GG-200 or GG-266
    1 and 2 4” Copper / 4” Steel (45° Angle) No Concrete or Block Wall No 5-1/2 in. diam W-J-1141 GG-200 or GG-266 (Walls only)
    2 4” Copper / 8” Steel No Concrete Slab / Block Wall No 10-1/2 in. diam C-AJ-1370 GG-266
    1 and 2 Multiple 1” Gas Tubing No Concrete Slab / Hollow-Core Floor / Block Wall No 4 in. diam C-AJ-1553 GG-266
    2 Multiple 3” Copper / 4” Steel No 2-1/2” Concrete Slab / Block Wall No 216 sq. in. C-AJ-1393 SL-100  / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 6” Steel Duct (28 gauge) No Concrete Slab / Block Wall No 8 in. diam C-AJ-7109 SL-100  / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 8” Steel Duct (26 gauge) No Concrete Slab / Block Wall No 10 in. diam C-AJ-7099 GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 24” by 12” Steel Duct No Concrete Slab / Block Wall No 325 sq. in. C-AJ-7064 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 36″ Steel No Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 6″ Copper / 24″ Steel 1” or 1-1/2” Mineral Fiber Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 FAN COIL UNIT (2-1/2” Copper) 1” Glass Fiber Concrete Slab / Block Wall No 128 sq. in. C-AJ-8090 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    1 LINE SET (1” Copper) 3/4” AB / PVC   Flexible Foam Concrete Slab / Hollow-Core Floor / Block Wal No 4 in. diam C-AJ-8174 GG-266
    2 LINE SET (1” Copper) 3/4” AB / PVC   Flexible Foam Concrete Slab / Hollow-Core Floor / Block Wal No 4 in. diam C-AJ-8091 GG-266
    2 (T Rating) Vitreous Water Closet with 3” Cast Iron Drain (Compression Coupling) No Concrete Slab No 4-1/2 in. diam or 4-1/2 by 5-1/2 in. Cone Shape F-B-1015 GG-200 / MW-300
    2 4” Copper / 8” Steel No Metal Deck Steel 10-1/2 in. diam F-A-1026 SL-100, GG-200 or GG-266 / MW-300
    1 4” Copper / 4” Steel / 1” & 2” Flexible Gas Pipe No Concrete Slab – Drywall Ceiling No 5-1/2 in. diam F-E-1019 GG-200 or GG-266
    1, 1-1/2 and 2 4″ Copper, Cast Iron, Steel No Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-1026 GG-200 / MW-300
    2 4″ Copper, Cast Iron, Steel No ISPAN System No 6-1/4 in. diam F-E-1027 GG-200 / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCTS
    CONCRETE – NONMETALLIC PIPE
    1 and 2 Multiple 3/4” PE-AL-PE, PEX-AL-PEX Composite Tubing No Concrete Slab / Hollow-Core Floor / Block Wal No 3 in. diam C-AJ-2365 GG-266
    2 Multiple 1” PEX, 3/4” PE- AL-PE, 3/4” PEX-AL-PEX Composite Tubing No 2-1/2” Concrete Slab /  Block Wall No 4 in. diam C-AJ-2443 GG-266
    2 Multiple 1” PEX No Concrete Slab / Block Wall No 48 sq. in. C-AJ-2504 GG-266
    2 1-1/2” FRPP No Concrete Slab / Block Wall No 3-1/8 in. diam C-AJ-2440 GG-266
    2 2” FRPP No 2-1/2” Concrete Slab /  Block Wall No 3-1/2 in. diam C-AJ-2546 GG-266
    1 2” FRPP No Concrete Slab / Hollow-Core Floor / Block Wall No 3 in. diam C-AJ-2548 GG-266
    1, 2 and 3 2” PVC, CPVC, ABS, PEX No Concrete Slab / Hollow-Core Floor / Block Wall Steel 3 in. diam C-AJ-2314 and C-AJ-2587 GG-266
    1 and 2 2” AquaRise No Concrete Slab / Hollow-Core Floor / Block Wall Steel 3 in. diam C-AJ-2314 GG-266
    2 and 3 2” PVC, CPVC, ABS, PEX No Concrete Slab Steel 3 in. diam C-AJ-2315 and C-AJ-2585 GG-266
    2 2” PVC, CPVC, ABS, PEX No 2-1/2” Concrete Slab No 3 in. diam C-AJ-2406 GG-266
    2 2” PVC, CPVC, ABS No Concrete Slab / Block Wall No 4 in. diam C-AJ-2537 GG-266
    2 2” PVC, CPVC, ABS,  PEX No 2-1/2” Concrete Slab No 3 in. diam F-A-2105 SL-100, GG-200 or GG-266 / FIREBAND
    2 3” and 4” PVC, CPVC No 2-1/2” Concrete Slab Steel (Req’d) 6 in. diam F-A-2133 GG-266 / TYPE-SSR / MW-300
    2 2″ PEX No Concrete Slab/ Concrete Wall No 3 in. diam C-BJ-2037 GG-266
    2 2″ AquaRise No Concrete Slab/ Concrete Wall No 3 in. diam C-BJ-2038 GG-266
    2 2” PVC, PEX No Concrete Slab No 2-1/2 to 3-1/4 in. Cone Shape F-A-2116 GG-266
    1 2” Climatherm, Fusiotherm No Concrete Slab / Hollow-Core Floor / Block Wall No. 3 in. diam C-AJ-2606 GG-200 or GG-266 / TYPE-SSC
    2 2” Climatherm, Fusiotherm No Concrete Slab / Concrete Wall No 3-1/4 to 4-1/2 in. Cone Shape C-BJ-2033 GG-266
    2 2” Climatherm, Fusiotherm No Concrete Slab / Concrete Wall No 3 to 3-3/8 in. Cone Shape C-BJ-2034 GG-266 / TYPE-SSC
    2 3” Climatherm, Fusiotherm No Concrete Slab / Concrete Wall No 4-1/2 to 4-7/8 in. Cone Shape C-BJ-2035 GG-266 / TYPE-SSC
    2 3” PVC, CPVC, ABS No Concrete Slab No 5 to 5-1/4 in. Cone Shape F-B-2024 GG-266
    2 3” XFR No Concrete Slab / Concrete Wall No 4-1/2 to 5-1/2 in. Cone Shape C-BJ-2030 GG-266 / MW-300 / GG-200
    2 4” PVC, CPVC, ABS No Concrete Slab No 5-1/2 to 6-1/4 in. Cone Shape F-B-2028 GG-266
    2 4” PVC, CPVC, ABS No Concrete Slab / Block Wall No 6-1/4 in. diam C-BJ-2027 GG-266
    2 4” PVC, CPVC No Concrete Slab / Concrete Wall No 6-1/4 to 7-1/2 in. Cone Shape C-BK-2039 GG-266
    2 4” XFR No Concrete Slab / Concrete Wall No 5-1/4 to 6-1/2 in. or  6-1/4 to 7-1/2 in. Cone Shape C-BJ-2029 GG-266
    2 2” PVC, ABS TUB DRAIN No Concrete Slab Steel (Req’d) 40 sq. in. F-A-2132 SL-100, GG-200 or GG-266 / FIREBAND / MW-300
    1 2” PVC, ABS No Concrete Slab No 96 sq. in. F-A-2111 SL-100, GG-200 or GG-266 / TYPE-SSC / MW-300
    2 2-1/4” Beverage Line (12 x 3/8” FRPE / Metallized Film / Fiberglass Jacket) No Concrete Slab / Block Wall No 3-1/8 in. diam C-AJ-2441 GG-266 / TYPE-SSC
    2 3-1/2” Beverage Line (12 x 1/2” PE or PEX, 2 x 3/8” Copper Freon) 3/4” AB /  PVC Flexible Foam Concrete Slab / Block Wall No 4-1/2 in. diam C-AJ-8136 GG-266 / TYPE-SSC
    1 2” Glass No Concrete Slab / Hollow-Core Floor / Block Wall No 3 in. diam C-AJ-2607 GG-266
    2 3” Glass No Concrete Slab / Block Wall No 4 in. diam C-AJ-2503 GG-200 or GG-266 / MW-300
    2 3” PVC, CPVC / 2” PEX No Concrete Slab / Block Wall No 4-5/8 in diam. C-AJ-2439 GG-200 or GG-266 / FIREBAND
    2 4” PVDF No Concrete Slab / Block Wall No 5 in. diam C-AJ-2405 GG-200 or GG-266 / TYPE-SSC / MW-300
    2 and 3 4” PVC, CPVC, ABS, FRPP, XFR / 3″ AquaRise No Concrete Slab / Block Wall No 5 in. diam C-AJ-2207 GG-200 or GG-266 / TYPE-SSC
    2 6” PVC, CPVC No Concrete Slab / Block Wall No 7 in. diam C-AJ-2584 GG-200 or GG-266 / TYPE-SSC
    2 2 x 1” PEX  +  4” Steel No Concrete Slab / Block Wall No 8 in. diam C-BJ-8018 GG-266 / MW-300
    2 Multiple 1” PEX, 3/4” PE- AL-PE, 3/4” PEX-AL-PEX Composite Tubing No Metal Deck No 4 in. diam C-AJ-2443 GG-266
    RATING (HR) PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCTS
    GYPSUM WALLBOARD – METALLIC PIPE and DUCTWORK
    1 Blank Opening No G.W.B. No 15 sq. in. W-L-0028 GG-200
    1 and 2 Multiple 1” Gas Tubing No G.W.B. No 4 in. diam W-L-1407 GG-266
    1 Multiple 2″ Steel No G.W.B. No 36 sq. in. W-L-1366 GG-200 or GG-266 / MW-300
    1 and 2 3″ Copper / 8″ Steel No G.W.B. No 10 in. diam W-L-1086 GG-200
    1 3” Cast Iron Stack with Membrane Stub-Out to 3” Cast Iron or PVC (Shielded Coupling) No G.W.B. No 4-1/2 in. diam W-L-1315 GG-266
    1 and 2 4” Copper, Steel (45° Angle) No G.W.B. No 5-1/2 in. diam W-L-1316 GG-200 or GG-266
    1 and 2 4” Cast Iron (Shielded Coupling) (45° Angle) No G.W.B. No 5-1/2 in. diam W-L-1371 GG-200 or GG-266
    1 and 2 4” Copper / 8” Steel No Shaft Wall Steel (Req’d) 11 in. diam W-L-1364 GG-200 or GG-266 / MW-300
    1 and 2 4” Copper, Steel 1” Glass or Mineral Fiber Shaft Wall Steel (Req’d) 8-1/2 in. diam W-L-5234 GG-266 / MW-300
    1 and 2 6″ Copper / 16″ Steel 1-1/2” Glass or Mineral Fiber G.W.B. No / Steel 21-3/4 in. diam W-L-5055 GG-266
    1 4” Dryer Vent / 8” Steel Duct (26 gauge) No G.W.B. No 10 in. diam W-L-7115 GG-200 or GG-266
    1 and 2 24” by 12” or 12” by 12” Steel Duct No G.W.B No 325 sq. in. W-L-7065 GG-200 / MW-300
    1 and 2 3″ Copper / 4″ Steel No G.W.B. No 585 sq. in. W-L-8012 GG-200 / MW-300
    1 and 2 6″ Copper / 6″ Steel 1” or 1-1/2” Mineral Fiber G.W.B. No 585 sq. in. W-L-8012 GG-200 / MW-300
    1 LINE SET (1” Copper) 3/4” AB / PVC   Flexible Foam G.W.B. No 4 in. diam W-L-8070 GG-266
    RATING (HR) PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCTS
    GYPSUM WALLBOARD – NONMETALLIC PIPE
    1 and 2 3/4” PE-AL-PE, PEX-AL-PEX Composite Tubing No G.W.B. No 3 in. diam W-L-2289 GG-266
    1 Multiple 1” PEX No G.W.B. No 16 sq. in. W-L-2421 GG-266
    2 2” PEX or Multiple 1” PEX No Shaft Wall No 4-1/2 in. diam W-L-2398 GG-266
    1 2” FRPP No G.W.B. No 3 in. diam W-L-2451 GG-266
    1 2″ PVC, CPVC No G.W.B. No 3 in. diam W-L-2422 GG-266
    1 and 2 2” PVC, CPVC, ABS, PEX, AquaRise No G.W.B. No 3 in. diam W-L-2145 GG-266
    1 and 2 2” PVC, CPVC No Shaft Wall No 3 in. diam W-L-2417 GG-266 / FIREBAND
    1 2” Glass No G.W.B No 3 in. diam W-L-2516 GG-266
    1 2” Climatherm, Fusiotherm No G.W.B. No 3 in. diam W-L-2515 GG-200 or GG-266 / TYPE-SSC
    1 2 x 3/4” PEX, PE-AL-PE, PEX-AL-PEX, 1-1/2” ABS or 2” PVC, XFR  Membrane Penetrations No G.W.B. No 3-3/8 in. diam W-L-2360 GG-266
    1 and 2 4” PVC, CPVC, ABS,  XFR / 3″ AquaRise No G.W.B. No 5 in. diam W-L-2143
    1 and 2 4” PVC, CPVC, ABS,  XFR / 2″ PP No G.W.B. No 5 in. diam W-L-2566 GG-200 or GG-266 / TYPE-SSC
    RATING (HR) PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCTS
    FRAMED FLOOR – METALLIC and NONMETALLIC PIPES
    1 4” Copper, Steel (Optional Chase Wall) No Wood Floor No 5-1/2 in. diam F-C-1093 GG-200
    1 4” Copper, Steel (Optional Chase Wall) No ISPAN System No 5-1/2 in. diam F-C-1151 GG-200
    1 2” Copper, Steel (Optional Chase Wall) 1/2 to 1” Glass or Mineral Fiber, 1/2 to 3/4” AB / PVC Flexible Foam Wood Floor No 4-1/2 in. diam F-C-5080 GG-266
    1 Multiple 2” PEX, 3/4” PE-AL-PE, 3/4” PEX-AL-PEX Composite Tubing (Optional Chase Wall) No Wood Floor No 4-1/2 in. diam F-C-2228 GG-266
    1 2” PVC, CPVC, ABS, PEX (Optional Chase Wall) No Wood Floor No 3 in. diam F-C-2200 GG-266
    1 3” PVC, CPVC, ABS, XFR (Chase Wall) No Wood Floor Steel Straps 4-1/2 in. by 5 in. F-C-2373 GG-266
    1 3” PVC, CPVC, ABS, XFR with 3” Branch Pipe or 2” P-Trap (Optional Chase Wall) No Wood Floor No 4 in. diam F-C-2345 GG-266 / TYPE-SSC
    1 4” PVC, CPVC, ABS, XFR (Optional Chase Wall) No Wood Floor No 5 in. diam F-C-2227 GG-266 / TYPE-SSC
    1 2” PVC, CPVC, ABS,  PEX (Optional Chase Wall) No ISPAN System No 3 in. diam F-C-2406 GG-266
    1 3” PVC, CPVC (Optional Chase Wall) No ISPAN System No 4-1/2 in. diam F-C-2028 GG-266 / FIREBAND
    1 3” PVC, CPVC, ABS, XFR with 3” Branch Pipe or 2” P-Trap (Optional Chase Wall) No ISPAN System No 4 in. diam F-C-2405 GG-266 / TYPE-SSC
    1 4” PVC, XFR, ABS, CPVC (Optional Chase Wall) No ISPAN System No 5 in. diam F-C-2025 (50 Pa) GG-200 or GG-266 / TYPE-SSC
  • UL Electrical Charts
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCT
    CONCRETE – METALLIC EMT and CONDUIT
    3 Blank Opening Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-0048 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    3 4″ EMT or Conduit Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-1227 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 and 3 4” EMT / 6” Conduit Concrete Slab / Block Wall Steel 8-1/2 in. diam C-AJ-1369 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” EMT / 6” Conduit 2-1/2” Concrete Slab No 8-1/2 in. diam C-AJ-1452 SL-100, GG-200 or GG-266 / MW-300
    2 (T Rating) 4”EMT / 6” Conduit Concrete Slab / Block Wall No 8-1/2 in. diam C-AJ-1554 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” EMT / 6” Conduit Concrete Slab No 8-1/2 in. diam F-A-1021 GG-200 / MW-300 (Underside Floor Application)
    2 4” EMT / 6” Conduit Concrete Slab No 8-5/8 to 9-1/8 in. Cone Shape F-A-1055 SL-100, GG-200 or GG-266 / MW-300 (Floors only)
    1 and 2 4″ EMT or Conduit Concrete Slab/ Hollow-Core Floor / Block Wall No 6 in. diam C-AJ-1201 GG-200 or GG-266
    1 and 2 4” EMT or Conduit (45° Angle) Concrete or Block Wall No 5-1/2 in. diam W-J-1141 GG-200 or GG-266 (Walls only)
    2 4” EMT / 6” Conduit Concrete Slab / Block Wall No 8-1/2 in. diam C-AJ-1370 GG-266
    2 Multiple 4” EMT or Conduit 2-1/2” Concrete Slab / Block Wall No 216 sq. in. C-AJ-1393 SL-100 / MW-300 (Floors only). GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4″ EMT or Conduit Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 4” EMT / 6” Conduit Metal Deck Steel 8-1/2 in. diam F-A-1026 SL-100, GG-200 or GG-266 / MW-300
    1 4” EMT or Conduit Concrete Slab – Drywall Ceiling No 5-1/2 in. diam F-E-1019 GG-200 or GG-266
    1, 1-1/2 and 2 4″ EMT or Conduit Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-1026 GG-200 / MW-300
    2 4″ EMT or Conduit ISPAN System No 6-1/4 in. diam F-E-1027 GG-200 / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCT
    CONCRETE – NONMETALLIC CONDUIT
    2 Multiple 1” ENT Concrete Slab / Block Wall No 4-1/8 in. diam C-AJ-2442 GG-266
    2 (T Rating) Multiple 1” ENT and BX Cables Concrete Slab / Block Wall No 8-1/2 in. diam C-BJ-8022 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    1, 2 and 3 2” ENT, FNMC, PVC Conduit Concrete Slab/ Hollow-Core Floor / Block Wall Steel 3 in. diam C-AJ-2314 and                     C-AJ-2587 GG-266
    2 and 3 2” ENT, FNMC, PVC Conduit Concrete Slab Steel 3 in. diam C-AJ-2315 and                     C-AJ-2585 GG-266
    2 2” ENT, FNMC, PVC Conduit 2-1/2” Concrete Slab No 3 in. diam C-AJ-2406 GG-266
    2 2” PVC Conduit Concrete Slab / Block Wall No 4 in. diam C-AJ-2537 GG-266
    2 2” ENT, FNMC, PVC Conduit 2-1/2” Concrete Slab No 3 in. diam F-A-2105 SL-100, GG-200 or GG-266 / FIREBAND
    2 3” and 4” PVC Conduit 2-1/2” Concrete Slab Steel (Req’d) 6 in. diam F-A-2133 GG-266 / TYPE-SSR / MW-300
    2 2” ENT, FNMC, PVC Conduit Concrete Slab No 2-1/2 to 3-1/4 in.                              Cone Shape F-A-2116 GG-266
    2 3” PVC Conduit Concrete Slab No 5 to 5-1/4 in.                                              Cone Shape F-B-2024 GG-266
    2 4” PVC Conduit Concrete Slab No 5-1/2 to 6-1/4 in.                               Cone Shape F-B-2028 GG-266
    2 4” PVC Conduit Concrete Slab / Block Wall No 6-1/4 in. diam C-BJ-2027 GG-266
    2 2” ENT, FNMC / 3” PVC Conduit Concrete Slab / Block Wall No 4-5/8 in. diam C-AJ-2439 GG-200 or GG-266 / FIREBAND
    3 4” PVC Conduit Concrete Slab / Block Wall No 5 in. diam C-AJ-2207 GG-200 or GG-266 / TYPE-SSC
    2 4” PVC Conduit Concrete Slab / Concrete Wall No 6-1/4 to 7-1/2 in.                                Cone Shape C-BK-2039 GG-266
    2 6” PVC Conduit Concrete Slab / Block Wall No 7 in. diam C-AJ-2584 GG-200 or GG-266 / TYPE-SSC
    2 2” ENT, FNMC, PVC Conduit Metal Deck No 3 in. diam C-AJ-2406 GG-266
    2 3” PVC Conduit Metal Deck Steel (Req’d) 5 in. diam F-A-2184 GG-200 or GG-266 / FIREBAND
    2 2” ENT, FNMC / 4” PVC Conduit Metal Deck No 5 in. diam F-A-2086 GG-200 / GG-266 / TYPE-SSC
    1, 1-1/2 and 2 2” PVC Conduit Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-2036 GG-266
    2 2” PVC Conduit ISPAN System No 3-1/2 in. diam F-E-2037 GG-266
    1 4” PVC Conduit Concrete Slab – Drywall Ceiling No 5 in. diam F-E-2023 GG-266 / TYPE-SSC
    1, 1-1/2 and 2 4″PVC Conduit Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-2034 GG-266 / TYPE-SSR / TYPE-SSC / MW-300
    2 4″PVC Conduit ISPAN System No 6-1/4 in. diam F-E-2035 GG-266 / TYPE-SSR / TYPE-SSC / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCT
    GYPSUM WALLBOARD – METALLIC EMT and CONDUIT
    1 Blank Opening G.W.B. No 15 sq. in. W-L-0028 GG-200
    1 Multiple 2” EMT or Conduit G.W.B. No 36 sq. in. W-L-1366 GG-200 or GG-266 / MW-300
    1 and 2 4″ EMT or Conduit G.W.B. No 6 in. diam W-L-1086 GG-200
    1 and 2 4” EMT or Conduit (45° Angle) G.W.B. No 5-1/2 in. diam W-L-1316 GG-200 or GG-266
    1 and 2 4” EMT or Conduit Shaft Wall Steel (Req’d) 11 in. diam W-L-1364 GG-200 / MW-300
    1 and 2 4″ EMT or Conduit G.W.B. No 585 sq. in. W-L-8012 GG-200 / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCT
    GYPSUM WALLBOARD – NONMETALLIC CONDUIT
    1 and 2 2” PVC Conduit G.W.B. No 3 in. diam W-L-2145 GG-266
    1 and 2 2” PVC Conduit Shaft Wall No 3 in. diam W-L-2417 GG-266 / FIREBAND
    1 and 2 4” PVC Conduit G.W.B. No 5 in. diam W-L-2143 GG-200 or GG-266 / TYPE-SSC
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCT
    FRAMED FLOOR – METALLIC EMT and CONDUIT / NONMETALLIC CONDUIT, ELECTRICAL CABLES
    1 4” EMT or Conduit  (Optional Chase Wall) Wood Floor No 5-1/2 in. diam F-C-1093 GG-200
    1 4” EMT or Conduit  (Optional Chase Wall) ISPAN System No 5-1/2 in. diam F-C-1151 GG-200
    1 2” ENT, FNMC, PVC Conduit (Optional Chase Wall) ISPAN System No 3 in. diam F-C-2406 GG-266
    1 3” PVC Conduit (Optional  Chase Wall) ISPAN System No 4-1/2 in. diam F-C-2028 GG-266 / FIREBAND
    1 4” PVC Conduit (Optional  Chase Wall) ISPAN System No 5 in. diam F-C-2025 GG-266 / TYPE-SSC
    1 2” ENT, FNMC, PVC Conduit (Optional Chase Wall) Wood Floor No 3 in. diam F-C-2200 GG-266
    1 4” PVC Conduit (Optional  Chase Wall) Wood Floor No 5 in. diam F-C-2227 GG-266 / TYPE-SSC
    1 Elect. / Comm. Cables (Optional  Chase Wall) Wood Floor No 3 in. diam F-C-3076 GG-200
    1 Elect. / Comm. Cables (Optional  Chase Wall) ISPAN System No 3 in. diam F-C-3100 GG-200
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) UL  SYSTEM Nos. PRODUCT
    CONCRETE and GYPSUM WALLBOARD – ELECTRICAL CABLES, CABLE TRAYS and BUSWAYS
    3 Elect. / Comm. Cables Concrete Slab / Steel, PVC 6 in. diam C-AJ-3113 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    1 and 2 Elect. / Comm. Cables Hollow-Core Floor / Block Wall No 4 in. diam C-AJ-3102 GG-200
    2 BX Cables Concrete Slab / Block Wall No 5 in. diam C-AJ-3251 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    1 NM Cables Hollow-Core Floor / Block Wall No 3 in. diam C-AJ-3255 GG-200
    2 Elect. / Comm. Cables Metal Deck No 4 in. diam F-A-3011 SL-100 or GG-200 / MW-300
    1 Elect. / Comm. Cables Concrete Slab – Drywall Ceiling No 3 in. diam F-E-3013 GG-200
    1, 1-1/2 and 2 Elect. / Comm. Cables Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-3017 GG-200 / MW-300
    2 Elect. / Comm. Cables ISPAN System No 3-1/2 in. diam F-E-3018 GG-200 / MW-300
    1 and 2 Elect. / Comm. Cables G.W.B. No 4 in. diam W-L-3067 GG-200
    1 and 2 Metal-Clad Cable G.W.B. No 2 in. diam W-L-3083 GG-200
    1 NM Cables G.W.B. No 3 in. diam W-L-3290 GG-200
    1 Elect / Comm. Cables G.W.B. No 48 sq. in. W-L-3305 GG-200 / MW-300
    2 36″ Aluminum / Steel Cable Trays Concrete Slab / Block Wall No 960 sq. in. C-AJ-4036 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    2 36″ Aluminum / Steel Cable Trays Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    1 and 2 18” Aluminum / Steel Cable Trays G.W.B. No  585 sq. in. W-L-4036 GG-200 / MW-300
    2 27” Busway Concrete Slab / Block Wall No 360 sq. in. C-AJ-6024 SL-100 / MW-300 (Floors only). GG-200 / MW-300 (Walls and Floors)
    1 and 2 23” Busway G.W.B. No 364 sq. in. W-L-6007 GG-200 / MW-300
  • cUL Architectural Listings
    RATING (Hr) JOINT TYPE JOINT WIDTH cUL SYSTEM Nos. PRODUCTS
    1 and 2 Head of G.W.B. to Metal Deck  (Optional Structural Steel Support) 1 in. nominal HW-D-0382 GG-200 / MW-300
    2 Head of Masonry Wall to Metal Deck     (Optional Structural Steel Support) 1 in. max HW-S-0021 and      HW-D-0459 GG-200 / MW-300
    1 and 2 Head of G.W.B. to Concrete Floor 1 in. max HW-S-0060 GG-200
    2 Concrete Floor Joint Incorporating Membrane Air Barrier 4 in. max FF-S-1031 SL-100 / MW-300
    2 Concrete Floor to Wall Joint Incorporating Membrane Air Barrier 4 in. max FW-S-1016 SL-100 / MW-300
    3 Horizontal Concrete Expansion Joint 4 in. nominal FF-D-1036 SL-100 / MW-300
    3 Vertical Concrete Expansion Joint 4 in. nominal WW-D-1036 GG-200 / MW-300
    2 Head of Masonry Wall to Concrete Floor 1 in. max HW-S-0079 GG-266
    3 Head of Masonry Wall to Concrete Floor 4 in. nominal HW-D-1032 GG-200 / MW-300
    3 Concrete Floor to Masonry Wall 4 in. nominal FW-D-1033 SL-100 / MW-300
    2 Stair Assembly 4 in. nominal FW-D-1045 GG-200 / MW-300
    slide content 1

  • cUL Mechanical Listings
    HOURLY FIRE RATING PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. Self-Seal® PRODUCT CODE
    CONCRETE – METALLIC PIPE and DUCTWORK
    3 Blank Opening No Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-0048  SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    3 3″ Copper / 4″ Steel / 4” Cast Iron (Shielded Coupling) No Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-1227 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 and 3 4” Copper / 8” Steel No Concrete Slab / Block Wall Steel 10-1/2 in. diam C-AJ-1369 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” Copper / 8” Steel No 2-1/2” Concrete Slab No 10-1/2 in. diam C-AJ-1452 SL-100, GG-200 or GG-266 / MW-300
    2 (FT Rating) 4” Copper / 10” Steel 2” or 3” Mineral Fiber Concrete Slab / Block Wall No 12 in. diam C-AJ-1554 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 (FT Rating) 4” Cast Iron (Optional Shielded Coupling) 1” Mineral Fiber Concrete Slab / Block Wall No 6 in. diam C-BJ-1005C SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 1-1/2” Copper / 2” Steel No Concrete Slab No 6 in. diam C-AJ-1019C GG-200 / MW-300 (Underside Floor Application)
    2 4” Copper / 8” Steel No Concrete Slab No 10-1/2 in. diam F-A-1021 GG-200 / MW-300 (Underside Floor Application)
    2 4” Copper / 8” Steel No Concrete Slab No 8-5/8 to 9-1/8 in. Cone Shape F-A-1055 SL-100, GG-200 or GG-266 / MW-300 (Floors only)
    2 3” Copper / 3” Steel 1” Glass Fiber Concrete Slab / Block Wall Steel 6 in. diam C-AJ-5163 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    3 3″ Copper / 4″ Steel 1” Mineral Fiber Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-5092 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 16” Steel 1” or 1-1/2” Mineral Fiber Concrete Slab / Block Wall No 576 sq. in. C-AJ-5093 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 and 3 3” Copper / 8” Steel 1”, 1-1/2” or 2” Glass Fiber Concrete Slab / Block Wall No 14 in. diam C-AJ-5204 and C-AJ-5307 GG-266 / MW-300
    2 6” Copper / 16” Steel 1-1/2”, 2”, 2-1/2” or 3” Cellular Glass Insulation Concrete Slab / Block Wall Steel 24 in. diam C-AJ-5228 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 (FT Rating) 4” Copper / 8” Steel with Optional Pipe Fittings 2”or 3” Mineral Fiber Concrete Slab / Block Wall No 10 in. diam C-AJ-5229 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 (FT Rating) 4” Copper, Steel, Cast Iron 3/4” AB / PVC   Flexible Foam Concrete Slab / Block Wall No 8 in. diam C-AJ-5293 GG-266 / MW-300 (Walls and Floors)
    1 and 2 3″ Copper / 4″ Steel No Concrete Slab / Hollow-Core Floor / Block Wall No 6 in. diam C-AJ-1201 GG-200 or GG-266
    1 and 2 4” Copper / 4″ Steel, Cast Iron     (45° Angle) No Concrete or Block Wall No 5-1/2 in. diam W-J-1141 GG-200 or GG-266 (Walls only)
    2 4” Copper / 8” Steel No Concrete Slab / Block Wall No 10-1/2 in. diam C-AJ-1370 GG-266
    1 and 2 Multiple 1” Gas Tubing No Concrete Slab / Hollow-Core Floor / Block Wall No 4 in. diam C-AJ-1553 GG-266
    2 Multiple 3” Copper / 4” Steel No 2-1/2” Concrete Slab / Block Wall No 216 sq. in. C-AJ-1393 SL-100  / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 6” Steel Duct (28 gauge) No Concrete Slab / Block Wall No 8 in. diam C-AJ-7109 SL-100  / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 8” Steel Duct (26 gauge) No Concrete Slab / Block Wall No 10 in. diam C-AJ-7099 GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 24” by 12” Steel Duct No Concrete Slab / Block Wall No 325 sq. in. C-AJ-7064 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 36″ Steel No Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 6″ Copper / 24″ Steel 1” or 1-1/2” Mineral Fiber Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 FAN COIL UNIT (2-1/2” Copper) 1” Glass Fiber Concrete Slab / Block Wall No 128 sq. in. C-AJ-8090 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    1 LINE SET (1” Copper) 3/4” AB / PVC   Flexible Foam Concrete Slab / Hollow-Core Floor / Block Wall No 4 in. diam C-AJ-8174 GG-266
    2 LINE SET (1” Copper) 3/4” AB / PVC   Flexible Foam Concrete Slab / Hollow-Core Floor / Block Wall No 4 in. diam C-AJ-8091 GG-266
    2 (FT Rating) Vitreous Water Closet with 3” Cast Iron Drain (Shielded Coupling) No Concrete Slab No 4-1/2 in. diam or 4-1/2 by 5-1/2 in.                      Cone Shape F-B-1015 GG-200 / MW-300
    2 4” Copper / 8” Steel No Metal Deck Steel 10-1/2 in. diam F-A-1026 SL-100, GG-200 or GG-266 / MW-300
    2 4” Copper / 4” Steel 1” Glass Fiber Metal Deck No 8 in. diam F-A-5006C SL-100, GG-200 or GG-266 / MW-300
    1 4” Copper / 4” Steel / 1” & 2” Flexible Gas Pipe No Concrete Slab – Drywall Ceiling No 5-1/2 in. diam F-E-1019 GG-200 or GG-266
    1, 1-1/2 and 2 4″ Copper, Cast Iron, Steel No Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-1026 GG-200 / MW-300
    2 4″ Copper, Cast Iron, Steel No ISPAN System No 6-1/4 in. diam F-E-1027 GG-200 / MW-300
    HOURLY FIRE RATING PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. Self-Seal® PRODUCT CODE
    CONCRETE – NONMETALLIC PIPE
    1 and 2 2” PEX No Concrete Slab / Hollow-Core Floor / Block Wall No 3 in. diam C-AJ-2012C (50 Pa) GG-266
    2 Multiple 2” PEX, 3/4” PE-AL-PE, 3/4″ PEX-AL-PEX Composite Tubing No Concrete Slab / Block Wall No 4 in. diam C-AJ-2029C (50 Pa) GG-266
    2 1-1/2” PEX No Concrete Slab / Block Wall Steel 4 in. diam C-AJ-2014C (50 Pa) GG-266 / MW-300
    2 2” PEX No Concrete Slab / Block Wall No 3 in. diam C-AJ-2030C (50 Pa) GG-266 / TYPE-SSC
    1 and 2 2” PVC, CPVC No Concrete Slab / Hollow-Core Floor / Block Wall Steel 3 in. diam C-AJ-2026C (50 Pa) GG-266
    2 2” PVC, CPVC No Concrete Slab Steel 3 in. diam C-AJ-2027C (50 Pa) GG-266
    2 2” PVC, CPVC No Concrete Slab / Block Wall No 3 in. diam C-AJ-2009C (50 Pa) GG-200 or GG-266 / FIREBAND
    2 2” PVC, CPVC, ABS, XFR No 2-1/2” Concrete Slab No 3 in. diam F-A-2015C (50 Pa) SL-100, GG-200 or GG-266 / FIREBAND
    2 2″ PVC (Schedule 80), AquaRise No 2-1/2” Concrete Slab No 3-1/2 in. diam F-A-2045C (50 Pa) GG-266
    2 3” and 4” PVC, CPVC No 2-1/2” Concrete Slab Steel (Req’d) 6 in. diam F-A-2016C (50 Pa) GG-266 / TYPE-SSR / MW-300
    2 2″ PEX No Concrete Slab/ Concrete Wall No 3 in. diam C-BJ-2008C (50 Pa) GG-266
    2 2” Climatherm, Fusiotherm No Concrete Slab / Concrete Wall No 3-1/4 to 4-1/2 in. Cone Shape C-BJ-2004C (50 Pa)  GG-266
    2 2” Climatherm, Fusiotherm No Concrete Slab / Concrete Wall No 3 to 3-3/8 in. Cone Shape C-BJ-2005C(50 Pa)  GG-266 / TYPE-SSC
    2 3” PVC, CPVC No Concrete Slab No 5 to 5-1/4 in. Cone Shape F-B-2003C (50 Pa) GG-266
    2 3” XFR No Concrete Slab / Concrete Wall No 4-1/2 to 5-1/2 in. Cone Shape C-BJ-2003C (50 Pa) GG-266 / MW-300 / GG-200
    2 4” PVC, CPVC No Concrete Slab No 5-1/2 to 6-1/4 in. Cone Shape F-B-2005C (50 Pa) GG-266
    2 4” PVC, CPVC No Concrete Slab / Concrete Wall No 6-1/4 to 7-1/2 in. Cone Shape C-BK-2001C (50 Pa) GG-266
    2 4” XFR No Concrete Slab / Concrete Wall No 5-1/4 to 6-1/2 in. or  6-1/4 to 7-1/2 in. Cone Shape C-BJ-2048 (50 Pa) GG-266
    2 Multiple 2” PVC, ABS, XFR  TUB DRAIN No Concrete Slab Steel (Req’d) 40 sq. in. F-A-2014C (50 Pa) SL-100, GG-200 or GG-266 / FIREBAND / MW-300
    1 and 2 2” PVC, ABS No Concrete Slab No 96 sq. in. F-A-2010C (50 Pa) SL-100, GG-200 or GG-266 / TYPE-SSC / MW-300
    1 2″ Glass No Concrete Slab / Hollow-Core Floor / Block Wall No 3 in. diam C-AJ-2607 GG-266
    2 3″ Glass No Concrete Slab / Block Wall No 4 in. diam C-AJ-2503 GG-200 or GG-266 / MW-300
    2 3” PVC, CPVC No Concrete Slab / Block Wall No 4-1/2 in. diam C-AJ-2010C (50 Pa) GG-200 or GG-266 / FIREBAND
    2 3” PVC, CPVC No Concrete Slab / Hollow-Core Floor / Block Wall No 4-1/2 in. diam C-AJ-2013C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 4″ ABS + Pipe Coupling No Concrete Slab / Hollow-Core Floor / Block Wall No 5 in. diam C-AJ-2077C (50 Pa) GG-200 or GG-266 / TYPE-SSR
    2 6” PVC, CPVC/ 4” XFR, ABS / 3″ AquaRise / 2” FRPP No Concrete Slab / Hollow-Core Floor / Block Wall No 7 in. diam C-AJ-2025C (50 Pa) GG-200 or GG-266 / TYPE-SSC
    2 6” PVC, CPVC / 4” FRPP No Concrete Slab / Hollow-Core Floor / Block Wall No 7 in. diam C-BJ-2001C (50 Pa) GG-200 or GG-266 / TYPE-SSC
    2 2″ PVC (Schedule 80), AquaRise No Metal Deck No 3-1/2 in. diam F-A-2045C (50 Pa) GG-266
    2 2” PEX No Metal Deck No 3 in. diam F-A-2033C (50 Pa) GG-266
    2 2” PVC, CPVC, ABS, XFR No Metal Deck No 3 in. diam F-A-2015C (50 Pa) SL-100, GG-200 or GG-266 / FIREBAND
    2 3” PVC, ABS, XFR No Metal Deck Steel (Req’d) 5 in. diam F-A-2032C (50 Pa) GG-200 or GG-266 / FIREBAND
    2 4” PVC, CPVC, XFR No Metal Deck No 5 in. diam F-A-2001C (50 Pa) GG-200 / GG-266 / TYPE-SSC/ MW-300
    2 4” XFR No Metal Deck Steel (Req’d) 6-1/4 in. diam F-A-2044C (50 Pa) GG-200 or GG-266 / TYPE-SSR / MW-300
    1, 1-1/2, and 2 2” PEX No Concrete Slab – Drywall Ceiling No 3 in. diam F-E-2001C (50 Pa) GG-266
    1, 1-1/2, and 2 2” PVC, CPVC, XFR No Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-2046 (50 Pa) GG-266
    1, 1-1/2,   and 2 2” PVC, CPVC No Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-2009C (50 Pa) GG-266
    2 2” PVC, CPVC, PEX No ISPAN System No 3-1/2 in. diam F-E-2010C (50 Pa) GG-266
    1, 1-1/2, and 2 3” PVC, CPVC No Concrete Slab – Drywall Ceiling No 4-1/2 in. diam F-E-2002C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 4” PVC, CPVC, ABS, XFR No Concrete Slab – Drywall Ceiling No 5 in. diam F-E-2023 (50 Pa) GG-266 / TYPE-SSC
    1, 1-1/2,   and 2 4″PVC, CPVC, XFR No Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-2007C (50 Pa) GG-266 / TYPE-SSR / TYPE-SSC / MW-300
    2 4″PVC, CPVC, XFR No ISPAN System No 6-1/4 in. diam F-E-2008C (50 Pa) GG-266 / TYPE-SSR / TYPE-SSC / MW-300
    HOURLY FIRE RATING PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. Self-Seal® PRODUCT CODE
    GYPSUM WALL BOARD – METALLIC PIPE and DUCTWORK
    1 Blank Opening No G.W.B. No 15 sq. in. W-L-0028 GG-200
    1 and 2 Multiple 1” Gas Tubing No G.W.B. No 4 in. diam W-L-1407 GG-266
    1 Multiple 2” Steel No G.W.B. No 36 sq. in. W-L-1366 GG-200  or GG-266 / MW-300
    1 and 2 3″ Copper / 8″ Steel No G.W.B. No 10 in. diam W-L-1086 GG-200
    1 3” Cast Iron Stack with Membrane Stub-Out to 3” Cast Iron or PVC (Shielded Coupling) No  G.W.B. No 4-1/2 in. diam W-L-1315 GG-266
    1 and 2 4” Copper / 4″ Steel, Cast Iron (45° Angle) No G.W.B. No 5-1/2 in. diam W-L-1316 GG-200 or GG-266
    1 and 2 4” Cast Iron (Shielded Coupling) (45° Angle) No G.W.B. No 5-1/2 in. diam W-L-1371 GG-200 or GG-266
    1 and 2 4” Copper / 8” Steel No Shaft Wall Steel (Req’d) 11 in. diam W-L-1364 GG-200  or GG-266 / MW-300
    1 and 2 4” Copper, Steel 1” Glass or Mineral Fiber Shaft Wall Steel (Req’d) 8-1/2 in. diam W-L-5234 GG-266 / MW-300
    1 and 2 6″ Copper / 16″ Steel 1-1/2” Glass or Mineral Fiber G.W.B. No / Steel 21-3/4 in. diam W-L-5055 GG-266
    1 4” Dryer Vent / 8” Steel Duct (26 gauge) No G.W.B. No 10 in. diam W-L-7115 GG-200 or GG-266
    1 and 2 24” by 12” or 12” by 12” Steel Duct No G.W.B No 325 sq. in. W-L-7065 GG-200 / MW-300
    1 and 2 3″ Copper / 4″ Steel No G.W.B. No 585 sq. in. W-L-8012 GG-200 / MW-300
    1 and 2 6″ Copper / 6″ Steel 1” or 1-1/2” Mineral Fiber G.W.B. No 585 sq. in. W-L-8012 GG-200 / MW-300
    1 LINE SET (1” Copper) 3/4” AB / PVC   Flexible Foam G.W.B. No 4 in. diam W-L-8070 GG-266
    HOURLY FIRE RATING PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. Self-Seal® PRODUCT CODE
    GYPSUM WALLBOARD – NONMETALLIC PIPE
    1 and 2 1” PEX No G.W.B. No 2-3/8 in. diam W-L-2012C (50 Pa) GG-266
    1 Multiple 1” PEX No G.W.B. No 16 sq. in. W-L-2033C (50 Pa) GG-266
    2 2” PEX or Multiple 1” PEX No Shaft Wall No 4-1/2 in. diam W-L-2029C (50 Pa) GG-266
    1 2″ Glass No G.W.B. No 3 in. diam W-L-2516 GG-266
    1 2” PVC, CPVC No G.W.B. No 3 in. diam W-L-2034C (50 Pa) GG-266
    1 2” PVC, CPVC, ABS, PEX No G.W.B. No 3 in. diam W-L-2036C (50 Pa) GG-266
    1 4″ ABS + Pipe Coupling No G.W.B. No 5 in. diam W-L-2059C (50 Pa) GG-200 or GG-266 / TYPE-SSR
    1 and 2 2” PEX, 3” PVC, CPVC No G.W.B. No 4-1/2 in. diam W-L-2013C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 and 2 4” PVC, CPVC,  XFR, ABS / 2″ PP No G.W.B. No 5 in. diam W-L-2566 (50 Pa) GG-200 or GG-266 / TYPE-SSC
    1 2 x 3/4” PEX, PE-AL- PE, PEX -AL-PEX, 1-1/2” ABS or 2” PVC, XFR Membrane Penetrations No G.W.B. No 3-3/8 in. diam W-L-2025C (50 Pa) GG-266
    1 and 2 4” PVC, CPVC (45° Angle) No G.W.B. Steel 5 in. diam W-L-2030C (50 Pa) GG-266 / FIREBAND
    HOURLY FIRE RATING PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. Self-Seal® PRODUCT CODE
    FRAMED FLOOR – METALLIC and NONMETALLIC PIPES
    1 4” Copper, Steel (Optional Chase Wall) No Wood Floor No 5-1/2 in. diam F-C-1093 GG-200
    1 4” Copper, Steel (Optional Chase Wall) No ISPAN System No 5-1/2 in. diam F-C-1151 GG-200
    1 2” Copper, Steel (Optional Chase Wall) 1/2 to 1” Glass or Mineral Fiber, 1/2 to 3/4” AB / PVC Flexible Foam Wood Floor No 4-1/2 in. diam F-C-5080 GG-266
    1 2” PVC, CPVC, ABS, PEX  (Optional Chase Wall) No Wood Floor No 3 in. diam F-C-2021C (50 Pa) GG-266
    1 2” PVC, CPVC, ABS,  PEX (Optional Chase Wall) No ISPAN System No 3 in. diam F-C-2406(50 Pa) GG-266
    1 2” PVC, CPVC, ABS, PEX (Optional Chase Wall) No Wood Floor No 3 in. diam F-C-2030C (50 Pa) GG-266 / TYPE-SSC
    1 3” PVC, CPVC, ABS, XFR (Chase Wall) No Wood Floor Steel Straps 4-1/2 in. by 5 in. F-C-2034C (50 Pa) GG-266
    1 3” PVC, CPVC (Optional Chase Wall) No Wood Floor No 4-1/2 in. diam F-C-2003C (50 Pa) GG-266 / FIREBAND
    1 3” PVC, CPVC(Optional Chase Wall) No ISPAN System No 4-1/2 in. diam F-C-2028 (50 Pa) GG-266 / FIREBAND
    1 3” PVC, CPVC, ABS, XFR with 3” Branch Pipe or 2” P-Trap (Optional Chase Wall) No Wood Floor No 4 in. diam F-C-2024C (50 Pa) GG-266 / TYPE-SSC
    1 3” PVC, CPVC, ABS, XFR with 3” Branch Pipe or 2” P-Trap (Optional Chase Wall) No ISPAN System No 4 in. diam F-C-2405 (50 Pa) GG-266 / TYPE-SSC
    2 3” PVC, CPVC (Optional Chase Wall) No Wood Floor No 4-1/2 in. diam F-C-2004C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 4” PVC, XFR, ABS, CPVC (Optional Chase Wall) No Wood Floor No 5 in. diam FF-C-2427 (50 Pa) GG-200 or GG-266 / TYPE-SSC
    1 4” PVC, XFR, ABS, CPVC (Optional Chase Wall) No ISPAN System No 5 in. diam F-C-2025 (50 Pa) GG-200 or GG-266 / TYPE-SSC
  • cUL Electrical Listings
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. PRODUCTS
    CONCRETE – METALLIC EMT and CONDUIT
    3 Blank Opening Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-0048 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    3 4″ EMT or Conduit Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-1227 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 and 3 4” EMT / 6” Conduit Concrete Slab / Block Wall Steel 8-1/2 in. diam C-AJ-1369 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” EMT / 6” Conduit 2-1/2” Concrete Slab No 8-1/2 in. diam C-AJ-1452 SL-100, GG-200 or GG-266 / MW-300
    2 (FT Rating) 4”EMT / 6” Conduit Concrete Slab / Block Wall No 8-1/2 in. diam C-AJ-1554 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 2” EMT / 2” Conduit Concrete Slab No 6 in. diam C-AJ-1019C GG-200 / MW-300 (Underside Floor Application)
    2 4” EMT / 6” Conduit Concrete Slab No 8-1/2 in. diam F-A-1021 GG-200 / MW-300 (Underside Floor Application)
    2 4” EMT / 6” Conduit Concrete Slab No 8-5/8 to 9-1/8 in.       Cone Shape F-A-1055 SL-100, GG-200 or GG-266 / MW-300 (Floors)
    1 and 2 4″ EMT or Conduit Concrete Slab / Hollow-Core Floor / Block Wall No 6 in. diam C-AJ-1201 GG-200
    1 and 2 4” EMT or Conduit (45° Angle) Concrete or Block Wall No 5-1/2 in. diam W-J-1141 GG-200 or GG-266 (Walls only)
    2 4” EMT / 6” Conduit Concrete Slab / Block Wall No 8-1/2 in. diam C-AJ-1370 GG-266
    2 Multiple 4” EMT or Conduit 2-1/2” Concrete Slab / Block Wall No 216 sq. in. C-AJ-1393 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4″ EMT or Conduit Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    2 4” EMT / 6” Conduit Metal Deck Steel 8-1/2 in. diam F-A-1026 SL-100, GG-200 or GG-266 / MW-300
    1 4” EMT or Conduit Concrete Slab – Drywall Ceiling No 5-1/2 in. diam F-E-1019 GG-200 or GG-266
    1, 1-1/2 and 2 4″ EMT or Conduit Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-1026 GG-200 / MW-300
    2 4″ EMT or Conduit ISPAN System No 6-1/4 in. diam F-E-1027 GG-200 / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. PRODUCTS
    CONCRETE – NONMETALLIC CONDUIT
    2 (FT Rating) Multiple 1” ENT and BX Cables Concrete Slab / Block Wall No 8-1/2 in. diam C-BJ-8022 SL-100 / MW-300 (Floors only) GG-200 or GG-266 / MW-300 (Walls and Floors)
    1 and 2 2” ENT, FNMC, PVC Conduit Concrete Slab / Hollow-Core Floor / Block Wall Steel 3 in. diam C-AJ-2026C (50 Pa) GG-266
    2 2” ENT, FNMC, PVC Conduit Concrete Slab Steel 3 in. diam C-AJ-2027C (50 Pa) GG-266
    2 2” ENT, FNMC, PVC Conduit 2-1/2” Concrete Slab No 3 in. diam F-A-2015C (50 Pa) SL-100, GG-200 or GG-266 / FIREBAND
    2 4” PVC Conduit 2-1/2” Concrete Slab Steel (Req’d) 6 in. diam F-A-2016C (50 Pa) GG-266 / TYPE-SSR / MW-300
    2 2” PVC Conduit Concrete Slab / Block Wall No 3 in. diam C-AJ-2009C (50 Pa) GG-200 or GG-266 / FIREBAND
    2 3” PVC Conduit Concrete Slab / Block Wall No 4-1/2 in. diam C-AJ-2010C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 and 2 3” PVC Conduit Concrete Slab / Hollow-Core Floor / Block Wall No 4-1/2 in. diam C-AJ-2013C (50 Pa) GG-200 or GG-266 / FIREBAND
    2 3” PVC Conduit Concrete Slab No 5 to 5-1/4 in.                                                  Cone Shape F-B-2003C (50 Pa) GG-266
    2 4” Conduit Concrete Slab No 5-1/2 to 6-1/4”          Cone Shape F-B-2005C (50 Pa) GG-266
    2 2” ENT, FNMC /  6” PVC Conduit Concrete Slab / Hollow-Core Floor / Block Wall No 7 in. diam C-AJ-2025C (50 Pa) GG-200 or GG-266 / TYPE-SSC
    2 4” PVC Conduit Concrete Slab / Concrete Wall No 6-1/4 to 7-1/2 in. Cone Shape C-BK-2001C (50 Pa) GG-266
    2 6” PVC Conduit Concrete Slab / Hollow-Core Floor / Block Wall No 7 in. diam C-BJ-2001C (50 Pa) GG-200 or GG-266 / TYPE-SSC
    2 2” ENT, FNMC, PVC Conduit Metal Deck No 3 in. diam F-A-2015C (50 Pa) SL-100, GG-200 or GG-266 / FIREBAND
    2 3” PVC Conduit Metal Deck Steel (Req’d) 5 in. diam F-A-2032C (50 Pa) GG-200 or GG-266 / FIREBAND
    2 4” PVC Conduit Metal Deck No 5 in. diam F-A-2001C (50 Pa) GG-200 / GG-266 / TYPE-SSC
    1, 1-1/2, and 2 2” PVC Conduit Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-2046 (50 Pa) GG-266
    1, 1-1/2, and 2 2” PVC Conduit Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-2009C (50 Pa) GG-266
    2 2” PVC Conduit ISPAN System No 3-1/2 in. diam F-E-2010C (50 Pa) GG-266
    1, 1-1/2, and 2 3” PVC Conduit Concrete Slab – Drywall Ceiling No 4-1/2 in. diam F-E-2002C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 4” PVC Conduit Concrete Slab – Drywall Ceiling No 5 in. diam F-E-2023 (50 Pa) GG-266 / TYPE-SSC
    1, 1-1/2,   and 2 4″PVC Conduit Concrete Slab – Drywall Ceiling No 6-1/4 in. diam F-E-2007C (50 Pa) GG-266 / TYPE-SSR / TYPE-SSC / MW-300
    2 4″PVC Conduit ISPAN System No 6-1/4 in. diam F-E-2008C (50 Pa) GG-266 / TYPE-SSR / TYPE-SSC / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. PRODUCTS
    GYPSUM WALLBOARD – METALLIC EMT and CONDUIT
    1 Blank Opening G.W.B. No 15 sq. in. W-L-0028 GG-200
    1 Multiple 2” EMT or Conduit G.W.B. No 36 sq. in. W-L-1366 GG-200 or GG-266 / MW-300
    1 and 2 4″ EMT or Conduit G.W.B. No 6 in. diam W-L-1086 GG-200
    1 and 2 4” EMT or Conduit            (45° Angle) G.W.B. No 5-1/2 in. diam W-L-1316 GG-200 or GG-266
    1 and 2 4” EMT or Conduit Shaft Wall Steel (Req’d) 11 in. diam W-L-1364 GG-200 / MW-300
    1 and 2 4″ EMT or Conduit G.W.B. No 585 sq. in. W-L-8012 GG-200 / MW-300
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. PRODUCTS
    GYPSUM WALLBOARD – NONMETALLIC CONDUIT
    1 2” PVC Conduit G.W.B. No 3 in. diam W-L-2034C (50 Pa) GG-266
    1 and 2 3” PVC Conduit G.W.B. No 4-1/2 in. diam W-L-2013C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 and 2 4” PVC Conduit G.W.B. No 5 in. diam W-L-2023C (50 Pa) GG-200 or GG-266 / TYPE-SSC
    1 and 2 4” PVC Conduit  (45° Angle) G.W.B. Steel 5 in . diam W-L-2030C (50 Pa) GG-266 / FIREBAND
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. PRODUCTS
    FRAMED FLOOR – METALLIC EMT and CONDUIT / NONMETALLIC CONDUIT, ELECTRICAL CABLES
    1 4” EMT or Conduit  (Optional Chase Wall) Wood Floor No 5-1/2 in. diam F-C-1093 GG-200
    1 4” EMT or Conduit  (Optional Chase Wall) ISPAN System No 5-1/2 in. diam F-C-1151 GG-200
    1 2” ENT, FNMC, PVC Conduit (Optional Chase Wall) Wood Floor No 3 in. diam F-C-2021C (50 Pa) GG-266
    1 2” ENT, FNMC, PVC Conduit (Optional Chase Wall) ISPAN System No 3 in. diam F-C-2406 (50 Pa) GG-266
    1 2” ENT, FNMC, PVC Conduit (Optional  Chase Wall) Wood Floor No 3 in. diam F-C-2030C (50 Pa) GG-266 / TYPE-SSC
    1 3” PVC Conduit (Optional  Chase Wall) Wood Floor No 4-1/2 in. diam F-C-2003C (50 Pa) GG-266 / FIREBAND
    1 3” PVC Conduit (Optional  Chase Wall) ISPAN System No 4-1/2 in. diam F-C-2028 (50 Pa) GG-266 / FIREBAND
    2 3” PVC Conduit             (Optional  Chase Wall) Wood Floor No 4-1/2 in. diam F-C-2004C (50 Pa) GG-200 or GG-266 / FIREBAND
    1 4” PVC Conduit  (Optional  Chase Wall) Wood Floor No 5 in. diam F-C-2427 (50 Pa) GG-266 / TYPE-SSC
    1 4” PVC Conduit (Optional  Chase Wall) ISPAN System No 5 in. diam F-C-2025 (50 Pa) GG-266 / TYPE-SSC
    1 Elect. / Comm. Cables (Optional Chase Wall) Wood Floor No 3 in. diam F-C-3076 GG-200
    1 Elect. / Comm. Cables (Optional Chase Wall) ISPAN System No 3 in. diam F-C-3100 GG-200
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) cUL  SYSTEM Nos. PRODUCTS
    CONCRETE and GYPSUM WALLBOARD – ELECTRICAL CABLES, CABLE TRAYS and BUSWAYS
    3 Elect. / Comm. Cables Concrete Slab / Block Wall Steel, PVC 6 in. diam C-AJ-3113 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    1 and 2 Elect. / Comm. Cables Hollow-Core Floor / Block Wall No 4 in. diam C-AJ-3102 GG-200
    2 BX Cables Concrete Slab / Block Wall No 5 in. diam C-AJ-3251 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    1 NM Cables Hollow-Core Floor / Block Wall No 3 in. diam C-AJ-3255 GG-200
    2 Elect. / Comm. Cables Metal Deck No 4 in. diam F-A-3011 SL-100 or GG-200 / MW-300
    1 Elect. / Comm. Cables Concrete Slab – Drywall Ceiling No 3 in. diam F-E-3013 GG-200
    1, 1-1/2 and 2 Elect. / Comm. Cables Concrete Slab – Drywall Ceiling No 3-1/2 in. diam F-E-3017 GG-200 / MW-300
    2 Elect. / Comm. Cables ISPAN System No 3-1/2 in. diam F-E-3018 GG-200 / MW-300
    1 and 2 Elect. / Comm. Cables G.W.B. No 4 in. diam W-L-3067 GG-200
    1 and 2 Metal-Clad Cable G.W.B. No 2 in. diam W-L-3083 GG-200
    1 NM Cables G.W.B. No 3 in. diam W-L-3290 GG-200
    1 Elect / Comm. Cables G.W.B. No 48 sq. in. W-L-3305 GG-200 / MW-300
    1 and 2 18” Aluminum / Steel Cable Trays G.W.B. No  585 sq. in. W-L-4036 GG-200 / MW-300
    2 36″ Aluminum / Steel Cable Trays Concrete Slab / Block Wall No 960 sq. in. C-AJ-4036 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 36″ Aluminum / Steel Cable Trays Concrete Slab / Block Wall No 24 sq. ft. C-AJ-8048 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 27” Busway Concrete Slab / Block Wall No 360 sq. in. C-AJ-6024 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    1 and 2 23” Busway G.W.B. No 364 sq. in. W-L-6007 GG-200 / MW-300
  • ULC Architectural Listings
    RATING (HR) JOINT TYPE JOINT WIDTH ULC system nos. PRODUCTS
    3 Horizontal / Vertical Concrete Joint 102 mm max JF1 MW-300
    2 and 3 Horizontal / Vertical Concrete Joint 50 to 75 mm max JF2 MW-300
    3 Horizontal / Vertical Concrete Joint 75 mm max JF3 MW-300
    4 Concrete Perimeter Edge to Curtainwall 243 mm max JF79 SL-100 / MW-300
    1 and 2 Head of G.W.B. to Metal Deck n/a HW19 GG-200 / MW-300
    2 Head of Masonry Wall to Metal Deck 25 mm max HW20 GG-200 / MW-300
    4 Horizontal Concrete Construction Joint 243 mm max JF79 SL-100 / MW-300
    4 Vertical Concrete Construction Joint 243 mm max JF80 GG-200 / MW-300
  • ULC Mechanical Listings
    RATING (HR) PIPE PENETRATION (Up to Size & Type) PIPE INSULATION (Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) ULC  SYSTEM Nos. PRODUCTS
    3 Blank Opening No Concrete Slab / Block Wall Steel, PVC 150 mm dia. SP769  SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 and 4 Blank Opening No Concrete Slab / Block Wall Steel 0.261 sq. m. SP116 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    3 and 4 3″ Copper / 4″ Steel No Concrete Slab / Block Wall Steel, PVC 150 mm dia. SP771  SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 4” Copper / 4” Steel No Concrete Slab / Block Wall Steel 152 mm dia. SP945 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 4” Copper / 4” Steel No Concrete Slab No 152 mm dia. SP943 GG-200 / MW-300 (Underside Floor Application)
    3 and 4 3″ Copper / 4″ Steel 1” Mineral Wool Fibre Concrete Slab / Block Wall Steel, PVC 150 mm dia. SP775 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 3” Copper /  3” Steel 1” Glass Fibre Concrete Slab / Block Wall Steel 152 mm dia. SP941 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 3″ Copper / 4″ Steel No Hollow-Core Floor / Block Wall No 150 mm dia. SP770 SL-100 (Floors only) GG-200 (Walls and Floors)
    2 4” Copper / 4” Steel No Concrete Slab / Block Wall No 152 mm dia. SP946 GG-266 (Walls and Floors)
    2 LINESET (1” Copper ) 3/4” AB / PVC Flexible Foam Concrete Slab / Block Wall No 102 mm dia. SP942 GG-266 (Walls and Floors)
    2 FAN COIL UNIT (2-1/2” Copper) 1” Glass Fibre Concrete Slab / Block Wall No 0.082 sq. m. SP940 SL-100 / MW-300 (Floors only) GG-200 / MW-300 (Walls and Floors)
    2 and 4 3″ Copper / 16″ Steel No Concrete Slab / Block Wall Steel 0.261 sq. m. SP116 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 24″ Steel No Concrete Slab / Block Wall No 2.27 sq. m. SP777 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 6″ Copper / 24″ Steel 1” or 1-1/2” Mineral Wool Fibre Concrete Slab / Block Wall No 2.27 sq. m. SP777 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 1” PEX (Closed Pipe) No Concrete Slab / Block Wall No 51 mm dia. SP944 GG-266 (Walls and Floors)
    2 2” PVC, CPVC (DWV Pipe) No Hollow-Core Floor / Block Wall No 76 mm dia. SPC48 GG-266 (Walls and Floors)
    2 2” PVC, CPVC (DWV Pipe) No Concrete Slab No 76 mm dia. SPC50 GG-266 (Walls and Floors)
    2 2” PVC, CPVC, FRPP (DWV Pipe) No Concrete Slab / Block Wall No 64 mm dia. SPC54 TYPE-SSC / GG-200 / GG-266  (Walls and Floors)
    2 4” PVC, CPVC (DWV Pipe) No Concrete Slab / Block Wall No 127 mm dia. SPC49 TYPE-SSC / GG-200 / GG-266 (Walls and Floors)
    2 3″ Copper / 4″ Steel No G.W.B. No 150 mm dia. SP778 GG-200
    2 6″ Copper / 16″ Steel 1” or 1-1/2” Mineral Wool Fibre G.W.B. No / Steel 553 mm dia. SP782 GG-200
    1 and 2 3″ Copper / 4″ Steel No G.W.B. No 0.378 sq. m. SP783 GG-200 / MW-300
    1 and 2 6″ Copper / 6″ Steel 1” or 1-1/2” Mineral Wool Fibre G.W.B. No 0.378 sq. m. SP783 GG-200 / MW-300
    1 3/4″ PVC, CPVC No G.W.B. No 57 mm dia. SP779 GG-200
    2 2” PVC, CPVC (Closed Pipe) No G.W.B No 76 mm dia. SP947 GG-266
    1 and 2 4” PVC, CPVC (DWV Pipe) No G.W.B. No 127 mm dia. SPC55 TYPE-SSC / GG-200 / GG-266
  • ULC Electrical Listings
    RATING (HR) PIPE PENETRATION (Up to Size & Type) FIRE-RATED, FLOOR / WALL  ASSEMBLY OPTIONAL SLEEVING (Type) RECTANGULAR OR CORED OPENING (Up to Size) ULC  SYSTEM Nos. PRODUCTS
    3 Blank Opening Concrete Slab / Block Wall Steel, PVC 150 mm dia SP769 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 and 4 Blank Opening Concrete Slab / Block Wall Steel 0.261 sq. m. SP116 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    3 and 4 4″ EMT or Conduit Concrete Slab / Block Wall Steel, PVC 150 mm dia. SP771 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 4” EMT or Conduit Concrete Slab / Block Wall Steel 152 mm dia. SP945 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 4” EMT or Conduit Concrete Slab No 152 mm dia. SP943 GG-200 / MW-300 (Underside Floor Application)
    2 4″ EMT or Conduit Hollow-Core Floor / Block Wall No 150 mm dia. SP770 SL-100 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 4” EMT or Conduit Concrete Slab / Block Wall No 152 mm dia. SP946 GG-266 (Walls and Floors)
    2 and 4 4″ EMT or Conduit Concrete Slab / Block Wall Steel 0.261 sq. m. SP116 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 4″ EMT or Conduit Concrete Slab / Block Wall No 2.27 sq. m. SP777 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 2” PVC ENT Concrete Slab / Block Wall No 76 mm dia. SPC50 GG-266 (Walls and Floors)
    2 2” PVC ENT Concrete Slab / Block Wall No 64 mm dia. SPC54 TYPE-SSC / GG-200 / GG-266 (Walls and Floors)
    2 4″ EMT or Conduit G.W.B. No 150 mm dia. SP778 GG-200
    1 and 2 4″ EMT or Conduit G.W.B. No 0.378 sq. m. SP783 GG-200 / MW-300
    2 2” PVC ENT G.W.B. No 76 mm dia. SP947 GG-266
    1 and 2 2” PVC ENT G.W.B. No 64 mm dia. SPC55 TYPE-SSC / GG-200 / GG-266 (Walls and Floors)
    3 Elect. / Comm. Cables Concrete Slab / Block Wall Steel, PVC 150 mm dia. SP773 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 Elect. / Comm. Cables Hollow-Core Floor / Block Wall No 100 mm dia. SP772 SL-100 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 and 4 Elect. / Comm. Cables Concrete Slab / Block Wall Steel 0.261 sq. m. SP116 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 Elect. / Comm. Cables G.W.B. No 100 mm dia. SP780 GG-200
    2 Metal-Clad Cable G.W.B. No 50 mm dia. SP781 GG-200
    2 and 4 36″ Aluminum / Steel Cable Trays Concrete Slab / Block Wall Steel 0.261 sq. m. SP116 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)
    2 36″ Aluminum / Steel Cable Trays Concrete Slab / Block Wall No 2.27 sq. m. SP777 SL-100 / MW-300 (Floors only)  GG-200 / MW-300 (Walls and Floors)